XMTC Series intelligent high speed and high precision voltage and current inspection instrument

XMTC series intelligent high speed and high precision voltage and current inspection instrument adopts related microcomputer technology chip,It has strong anti-interference ability, can cooperate with different transformers to meet the requireme

Back to list

Product descriptionTechnical indexApplication fieldDownload

Summary:

       XMTC series intelligent high speed and high precision voltage and current inspection instrument adopts related microcomputer technology chip,It has strong anti-interference ability, can cooperate with different transformers to meet the requirements of various measurement ranges, and can realize high-precision display, control, transmission output, communication and other functions for multi-channel current.


Specifications:

Model

Display

Working power supply

Measurement parameters

Permitted Overload

XMTC-16B

Nixie tube display

 

AC220±10%,50/60Hz

AC current, maximum range 5A

120%×maximum range

75mV DC voltage, corresponding to the maximum range of external shunt 9999a

200%× 75mV

XMTC-16T

LCD display

 

 Control panel:

圖片1.png

                     
 XMTC-16B panel

              NOTE:  XMTC-16t is a liquid crystal display, and the panel content is similar   

① PV display

②indicator light

·UA,UB,UC:Yellow LED,Input line voltage indicator

·Ua ,Ub ,Uc:Green LED,Output line voltage indicator

·Ia,Ib,Ic: Red LED,Output current indicator

·AUTO:Automatic inspection mode

·MANU:Manual mode

·ALM:Detection point alarm indicator

③Set key

·Enter, confirm, exit setting state, switch setting items

④Shift key

·Blink bit shift operation to enter the current menu value. Switching between manual and automatic inspection status

⑤Decrement key

·Causes the display value of the flicker bit to cycle minus 1 or to point to the next specified value

⑥add keys

·Causes the display value of the flicker bit to increment by 1 or point to the previous specified value

⑦The unit of display data